Send Message

Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable

500 M
MOQ
On Request
Price
Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable
Features Gallery Product Description Request A Quote
Features
Specifications
Voltage: 0.6/1kV
Conductor: Bear Copper Cl.2
No. Of Conductor: Single Core
1st Insulation: Mica Tape
2nd Insualtion: XLPE
Sheath: LSZH
High Light:

fire rated electrical cable

,

fireproof electrical cable

,

IEC 60332 fire resistant multicore cable

Basic Infomation
Place of Origin: Mainland China
Brand Name: Chengtiantai cable
Certification: CE,CB
Model Number: FR-Cable
Payment & Shipping Terms
Packaging Details: Steel wooden Drum
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Product Description

Fire resistant cable 0.6/1kV single core | cu-conductor, mica tape, XLPE Insulation, LSZH Sheath

 

Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
6. Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

Physical and Electrical Characteristics:

 

 

SINGLE CORE CABLE (UNARMOURED) Physical and Electrical Characteristics:

 

No.cores x
cross-sec.
Insulation
thickness

Nominal

Sheath
thickness

Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
1×1.5 0.8 1.4 6.1 61 24 29 12.1
1×2.5 0.8 1.4 6.5 74 31 38 7.41
1×4.0 1.0 1.4 7.4 100 41 49 4.61
1×6.0 1.0 1.4 7.9 124 52 61 3.08
1×10 1.0 1.4 9.2 183 72 83 1.83
1×16 1.0 1.4 10.3 251 95 105 1.15
1×25 1.2 1.4 12.0 367 120 135 0.73
1×35 1.2 1.4 13.1 475 150 160 0.52
1×50 1.4 1.4 14.9 618 180 195 0.39
1×70 1.4 1.4 16.9 840 230 240 0.27
1×95 1.6 1.5 19.3 1134 280 285 0.19
1×120 1.6 1.5 21.1 1384 325 325 0.15
1×150 1.8 1.6 23.1 1683 375 365 0.12
1×185 2.0 1.7 25.6 2084 430 415 0.10
1×240 2.2 1.8 28.9 2696 510 480 0.08
1×300 2.4 1.9 31.7 3355 585 545 0.06
1×400 2.6 2.0 33.0 4246 690 625 0.05
1×500 2.8 2.1 37.2 5092 800 710 0.04
1×630 2.8 2.2 40.5 6362 920 810 0.03

 

 

 

 

INSTALLATION METHOD DETAILS

 

Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 0   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 1   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 2   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 3
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
 
Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 4   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 5   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 6   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 7
B1 – Electroduct in brickwork (Single-core)   B1 – Electroduct in brickwork (multi-core)   C – On the wall    C – On the ceiling
             
Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 8   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 9   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 10   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 11
C – Non-perforated tray   F – Perforated tray (Single-core)   F – Perforated tray (multi-core)   F –Suspended (Single-core)
             
Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 12   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 13   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 14   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 15
E – Suspended (multi-core)   B2 – Construction space   B2 – Construction space   B1 – Electroduct (Single-core)
             
Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 16   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 17   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 18   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 19
B2 – Electroduct (Multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B2 – Closed raceway embedded in floor (multi-core)   B1 – Ventilated raceway embedded in floor
             
Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 20   Cu - Conductor Fireproof Electrical Cable , Indoor Fire Resistant Power Cable 21        
C – Embedded in the brickwork   D – Buried in additional mechanical protection        

 

 

Cable Drum Data

 

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 60502 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

 

 

  RECOMMENDED ORDERING PARAMETERS

   CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

 

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

 

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

 

 

  WARRANTY

 

 

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

 
 
Recommended Products
Get in touch with us
Contact Person : Annie Chen
Tel : +8613670012325
Fax : 86-755-29886488
Characters Remaining(20/3000)